Quick answer
Start by checking whether the bedroom has its own indoor head and whether it shares an outdoor unit with another room. A bedroom that overheats with its own head presents a different question from a bedroom that receives air only through the doorway.
Keep a one-night comfort record
Record the mode and setpoint in each active zone before bed. Place a room thermometer near the occupied part of the bedroom, away from the discharge air, direct sunlight and other heat sources. Note the door position, the number of occupants and the room reading before bed and when the discomfort occurs. A controller displaying a target temperature and a thermometer showing room temperature are reporting different things.
What your observations can establish
Suppose you select 68°F at bedtime and later measure 74°F near the bed. Those figures document a six-degree difference at that location and time. They cannot identify a failed sensor or prove the equipment is oversized. Note whether another room was calling for heat and whether you observed warm discharge or simply heard a fan. Keep the model numbers with the readings.
Three questions for the technician
- Which sensor controls this indoor unit with our current controller and settings?
- How does this equipment combination operate when only the other room needs heat?
- How does the selected indoor unit’s minimum output compare with this bedroom’s load during mild weather?
For model selection, see PNNL’s sizing and selection guide. Keep the measured temperatures and photos in the service log so a technician can reproduce the circumstances.